Instrumental Methods of Analysis Important Questions (Unit-wise, BP701T)

Instrumental Methods of Analysis Important Questions (Unit-wise, BP701T)

By Last Bench Pharmacist, B.Pharm graduate · Updated November 2026

Instrumental Methods of Analysis (IMA) is the Semester 7 paper where diagrams win marks. Every technique, from UV-visible spectroscopy to HPLC, is asked the same way: principle, instrumentation with a labelled block diagram, and applications.

Below are the IMA important questions, unit-wise, following the PCI 2016-17 syllabus (BP701T). ★ marks the most-asked questions. Two sample answers show the exam format, and the MCQs at the end let you test yourself.

Want every answer written out? The B.Pharm Sem 7 Exam Pack has model answers for the ★ questions in IMA and every other Sem 7 theory paper. ₹99. See the pack →

Instrumental Methods of Analysis exam pattern (BP701T)

SectionQuestionsMarks
I. Objective (MCQs / fill in the blanks / one-word)10 × 2 (or 20 × 1)20
II. Long answersAnswer 2 of 3 × 1020
III. Short answersAnswer 7 of 9 × 535
Total3 hours75

For every instrument, write principle → instrumentation (block diagram) → working → advantages and limitations → applications. A clean block diagram is often worth half the marks.

Instrumental Methods of Analysis important questions, unit-wise

★ marks the questions asked most often in university papers. Prepare these first.

Unit I: UV–visible spectroscopy and fluorimetry

Long (10 marks)

  • ★ Explain the theory of UV–visible spectroscopy: electronic transitions, chromophores, auxochromes and spectral shifts. Derive the Beer–Lambert law and discuss its deviations.
  • ★ Describe the instrumentation of a double-beam UV–visible spectrophotometer (sources, monochromators, cells, detectors) and its applications.
  • ★ Explain the theory of fluorescence, the factors affecting it, quenching, instrumentation of a spectrofluorimeter and applications.

Short (5 marks)

  • ★ Photomultiplier tube · Single vs double beam · Multicomponent analysis · Spectrophotometric titrations
  • ★ Jablonski diagram · Quenching · Fluorescence vs phosphorescence · Woodward–Fieser rules (outline)

Unit II: IR, flame photometry, AAS, nepheloturbidimetry

Long

  • ★ Explain the principle of IR spectroscopy, molecular vibrations and the factors affecting vibrational frequencies. Describe the IR instrumentation and sampling techniques.
  • ★ Describe the principle, instrumentation, interferences and applications of atomic absorption spectroscopy.

Short

  • ★ FTIR · IR detectors (thermocouple, bolometer, Golay cell, pyroelectric) · IR sources (Nernst glower, globar)
  • ★ Flame photometry (principle, instrumentation, interferences) · Hollow cathode lamp · Nephelometry and turbidimetry

Unit III: Chromatography basics, column, TLC, paper, electrophoresis

Long

  • ★ Classify chromatography. Describe thin layer chromatography: principle, preparation of plates, development, detection, Rf value and applications.
  • Describe column chromatography (adsorption and partition).

Short

  • ★ Paper chromatography (types of development: ascending, descending, radial, 2-D) · Rf and factors affecting it
  • ★ Electrophoresis: principle, factors, types (paper, gel, capillary), applications

Unit IV: Gas chromatography and HPLC

Long

  • ★ Describe the principle, instrumentation and applications of gas chromatography (carrier gases, columns, detectors).
  • ★ Describe the principle, instrumentation and applications of HPLC (pumps, injectors, columns, detectors).

Short

  • ★ FID · ECD · TCD · Derivatisation in GC · Temperature programming
  • ★ Normal vs reversed phase · Theoretical plates, resolution, retention time, system suitability · Gradient vs isocratic elution · UV/PDA detector

Unit V: Ion exchange, gel and affinity chromatography

Short

  • ★ Ion exchange chromatography: resins, mechanism, factors, applications (water demineralisation)
  • ★ Gel (size exclusion) chromatography · Affinity chromatography

B.PHARM SEMESTER 7 EXAM PACK

All the IMA questions above with model answers for every ★ question and practice MCQs, plus every other Sem 7 theory subject, in one PDF. Instant download. ₹99 ₹199

See what’s inside →

Sample model answers

Here are 2 answers written the way examiners like them. The pack has model answers for every ★ question.

Theory of UV–visible spectroscopy and the Beer–Lambert law (10 marks)

Principle: when a molecule absorbs UV (200–400 nm) or visible (400–800 nm) radiation, electrons are promoted from the ground state to a higher excited electronic state. The wavelength of maximum absorption (λmax) and the intensity depend on the structure of the molecule.

Electronic transitions (in order of decreasing energy):

TransitionEnergy / regionExample
σ → σ*Highest energy; below 150 nm (vacuum UV)Saturated hydrocarbons (methane, 125 nm)
n → σ*150–250 nmCompounds with lone pairs: alcohols, amines, alkyl halides
π → π*200–700 nm; high intensity (ε 10³–10⁵)Alkenes, aromatics, conjugated systems
n → π*Lowest energy (270–350 nm); low intensity (ε 10–100); forbiddenCarbonyl compounds, nitro, azo groups
  • Allowed transitions (π → π*) are intense; forbidden transitions (n → π*) are weak.

Chromophore: a group that absorbs UV or visible radiation (it contains π electrons): C=C, C=O, N=N, NO₂, C≡N, aromatic rings.

Auxochrome: a saturated group with lone pairs that does not absorb by itself but, when attached to a chromophore, shifts λmax to a longer wavelength and increases intensity: –OH, –NH₂, –OR, –Cl, –SH.

Spectral shifts:

ShiftMeaningCause
Bathochromic (red shift)λmax moves to a longer wavelengthConjugation, auxochromes, solvent effects (π → π* in polar solvents), alkaline pH for phenols
Hypsochromic (blue shift)λmax moves to a shorter wavelengthLoss of conjugation; n → π* in polar solvents; acid pH for anilines (lone pair protonated)
HyperchromicIncrease in absorbance (intensity)Auxochromes, conjugation
HypochromicDecrease in absorbanceDistortion of geometry (steric hindrance)

Beer–Lambert law:

  • Lambert’s law: when monochromatic light passes through an absorbing medium, the rate of decrease of intensity with thickness is proportional to the intensity of the light: −dI/db = kI.
  • Beer’s law: the rate of decrease of intensity is proportional to the concentration of the absorbing species: −dI/dc = k′I.
  • Combined (derivation): −dI/I = k·c·db. Integrating from I₀ to I and 0 to b: ln(I₀/I) = k·c·b. Converting to log₁₀:
    • A = log (I₀/I) = εbc
    • A = absorbance; ε = molar absorptivity (L mol⁻¹ cm⁻¹); b = path length (cm, usually 1 cm); c = concentration (mol/L).
    • Transmittance T = I/I₀; A = −log T = 2 − log %T.
    • When concentration is in g/100 mL (1% w/v) and b = 1 cm, the absorptivity is A(1%, 1 cm) (the specific absorbance, used in the IP).

Deviations from the Beer–Lambert law:

  1. Real (fundamental) deviations: the law holds only for dilute solutions (below about 0.01 M). At high concentrations, molecular interactions and changes in refractive index alter ε.
  2. Chemical deviations: association, dissociation, ionisation, complexation, polymerisation or reaction with the solvent changes the absorbing species. Example: dichromate–chromate equilibrium (pH dependent); benzoic acid dimerises.
  3. Instrumental deviations:
    • Polychromatic radiation (the law assumes monochromatic light).
    • Stray light.
    • Mismatched cells.
    • Fluorescence of the sample; scattering by turbid solutions; detector non-linearity.

HPLC (10 marks)

Principle: high performance liquid chromatography separates components by passing a liquid mobile phase under high pressure (up to 400 bar / 6000 psi; UHPLC up to 1000 bar or more) through a column packed with very small particles (3–10 µm; sub-2 µm in UHPLC). Separation may be by partition, adsorption, ion exchange or size exclusion.

Types:

  • Normal phase HPLC: polar stationary phase (silica, cyano, amino) and non-polar mobile phase (hexane, chloroform). Polar compounds elute last.
  • Reversed-phase HPLC (RP-HPLC) (about 80% of applications):
    • Non-polar stationary phase: silica bonded with C18 (octadecylsilane, ODS), C8 or phenyl groups.
    • Polar mobile phase: water or buffer + methanol / acetonitrile.
    • Polar compounds elute first; non-polar compounds are retained longer.
  • Ion exchange, size exclusion, chiral and affinity HPLC; ion-pair chromatography (an ion-pairing reagent such as octane sulphonate for ionised bases).

Instrumentation: solvent reservoir (with degasser) → pump → injector → (guard column) → analytical column (in an oven) → detector → data system.

  1. Solvent reservoirs and degassing:
    • HPLC-grade solvents, filtered (0.45 µm membrane) and degassed (to remove dissolved air, which forms bubbles in the pump and detector).
    • Degassing methods: sonication, helium sparging, vacuum, in-line vacuum degassers.
  2. Pumps: must deliver a constant, pulse-free flow (0.1–10 mL/min) at high pressure.
    • Reciprocating (piston) pumps (the most common): dual-piston designs with pulse dampers to reduce pulsation.
    • Syringe (screw-driven) pumps: pulse-free but limited volume.
    • Constant pressure (pneumatic) pumps.
    • Isocratic elution: a constant mobile-phase composition.
    • Gradient elution: the composition changes during the run (e.g. increasing acetonitrile), via low-pressure or high-pressure mixing. Improves the separation of complex mixtures with a wide polarity range and shortens run times.
  3. Injector:
    • Rheodyne (six-port) loop injector valve: the sample is filled into a fixed-volume loop (e.g. 20 µL) at atmospheric pressure, then the valve is turned to place the loop in the mobile-phase stream. Accurate and reproducible.
    • Autosamplers (automatic injection).
  4. Columns:
    • Guard column: a short column before the analytical column; protects it from particles and strongly retained impurities.
    • Analytical column: stainless steel, 10–25 cm long, 4.6 mm internal diameter, packed with 5 µm particles (common). Also preparative columns (larger).
    • Column oven (constant temperature, e.g. 25–40 °C) improves reproducibility.
  5. Detectors:
DetectorPrinciple / use
UV–visible (fixed or variable wavelength)The most common; for compounds with chromophores
Photodiode array (PDA / DAD)Records the full UV spectrum of each peak: peak purity and identification
FluorescenceVery sensitive and selective for fluorescent compounds (or derivatives)
Refractive index (RI)Universal; for compounds without chromophores (sugars, polymers); not usable with gradients; less sensitive
Electrochemical (amperometric)Oxidisable or reducible compounds (catecholamines)
ConductivityIons (ion chromatography)
Evaporative light scattering (ELSD)Non-volatile compounds without chromophores; gradient compatible
Mass spectrometer (LC–MS, LC–MS/MS)Identification and very sensitive quantification (bioanalysis, impurities)
  1. Data system (integrator / chromatography software).

Chromatographic parameters (system suitability):

  • Retention time (tR): the time from injection to the peak maximum. Dead time (t₀ or tM): for an unretained compound.
  • Capacity factor (retention factor) k′ = (tR − t₀)/t₀ (ideally 2–10).
  • Selectivity (separation factor) α = k′₂/k′₁ (must be more than 1).
  • Resolution Rs = 2(tR₂ − tR₁)/(W₁ + W₂). Rs of 1.5 or more means baseline separation (system suitability usually requires Rs > 2).
  • Number of theoretical plates (column efficiency): N = 16 (tR/W)² or 5.54 (tR/W½)². HETP (height equivalent to a theoretical plate) = L/N. The van Deemter equation: H = A + B/u + C·u (A = eddy diffusion, B = longitudinal diffusion, C = mass transfer resistance; u = linear velocity).
  • Tailing factor (asymmetry) T = W₀.₀₅/2f: ideally 1; usually required to be not more than 2.
  • %RSD of replicate injections: usually not more than 2%.

Quantitative analysis:

  • External standard method (comparison of peak areas with a standard).
  • Internal standard method (a known compound added to both the sample and the standard; corrects for injection variability).
  • Area normalisation; standard addition.

Applications:

  • Assay of drugs in bulk and formulations (most IP / USP monographs).
  • Related substances / impurity profiling, stability-indicating methods (forced degradation).
  • Dissolution testing.
  • Bioanalysis (drug levels in plasma; bioequivalence studies; TDM).
  • Herbal drug standardisation (marker compounds).
  • Chiral separations; preparative purification of compounds.
  • Food, environmental and clinical analysis.

Advantages over GC: non-volatile and thermally unstable compounds can be analysed (most drugs), and no derivatisation is needed. Over classical column chromatography: speed, resolution, sensitivity, automation and reproducibility.

5 practice MCQs with answers

1. The transition with the lowest energy is:

  • a) n → σ*
  • b) π → π*
  • c) n → π*
  • d) σ → σ*
Show answer

Answer: c. It occurs in carbonyl compounds at 270–350 nm with low intensity.

2. An auxochrome attached to a chromophore usually causes a:

  • a) Bathochromic shift
  • b) Hypochromic shift
  • c) No change
  • d) Hypsochromic shift
Show answer

Answer: a. –OH and –NH₂ shift λmax to longer wavelengths.

3. Beer’s law relates absorbance to:

  • a) Wavelength only
  • b) Path length only
  • c) Concentration
  • d) Temperature
Show answer

Answer: c. Lambert’s law relates it to path length; together A = εbc.

4. Cuvettes for measurements in the UV region must be made of:

  • a) Glass
  • b) Plastic
  • c) Quartz
  • d) NaCl
Show answer

Answer: c. Glass absorbs below about 340 nm.

5. The source of radiation for the UV region is:

  • a) Nernst glower
  • b) Hollow cathode lamp
  • c) Tungsten lamp
  • d) Deuterium lamp
Show answer

Answer: d. Tungsten is used for the visible region.

Free Instrumental Methods of Analysis notes, unit-wise

Related guides

Frequently asked questions

Which units are most important in IMA?

Unit I (UV-visible spectroscopy and the Beer–Lambert law), Unit II (IR and atomic absorption) and Unit IV (gas chromatography and HPLC) supply most of the 10-mark questions.

How should I draw instrumentation diagrams?

Draw a simple block diagram in the order the light or sample travels: source → wavelength selector → sample cell → detector → recorder. Label every block.

How is the 75-mark paper divided?

Most universities follow the PCI pattern: 20 marks of objective questions, 2 of 3 long answers (10 marks each) and 7 of 9 short answers (5 marks each), in 3 hours. The other 25 marks are internal assessment.

Is this based on the PCI syllabus?

Yes. It follows the PCI B.Pharm 2016-17 syllabus (Regulations 2014), which applies to students admitted before 2026-27. The new 2026-27 syllabus uses different course codes. Check a recent paper from your university, as a few universities use a different marks split.

B.PHARM SEMESTER 7 EXAM PACK

All the IMA questions above with model answers for every ★ question and practice MCQs, plus every other Sem 7 theory subject, in one PDF. Instant download. ₹99 ₹199

See what’s inside →

About the Author

Last Bench Pharmacist

B.Pharm graduate working at one of the top pharma and healthcare companies. Writes the free PCI-syllabus notes, unit-wise important questions, exam guides and study packs on Last Bench Pharmacist for B.Pharm, Pharm D, GPAT and NIPER students.

You may also like these